High Frequency Online UPS HP9335C Plus 10-30KVA Factory Price

High Frequency Online UPS HP9335C Plus 10-30KVA Factory Price

  • 3Ph in / 3Ph out Online UPS,isolation transformer offer full isolation
  • Support N+X parallel redundancy and Maintenance bypass
  • EPO/ECO/SNMP/USB/RS232 optional.
  • True double-conversion
  • DSP technology guarantees high performance
  • Output power factor 0.9

PRODUCT DESCRIPTION

Key Features:

  1. True double-conversion
  2. DSP technology guarantees high performance
  3. Output power factor 0.9
  4. Wide input voltage range (110-300 VAC)
  5. Active power factor correction in all phases
  6. 50Hz/60Hz frequency converter mode
  7. ECO mode operation for energy saving
  8. Accepts dual-mains inputs
  9. Emergency power off function (EPO)
  10. Generator compatible
  11. SNMP+USB+RS-232 multiple communications
  12. 3-stage extendable charging design for optimized battery performance
  13. Adjustable battery numbers
  14. Maintenance bypass available
  15. Optional N+X parallel redundancy
  16. Optional isolation transformer offers full isolation and complete common mode noise rejection

Parameter

MODELHP9335C Plus 10-30KVA
10K10K-XL15K15K-XL20K20K-XL30K30K-XL
CAPACITY10KVA / 9KW 15KVA / 13.5KW 20KVA / 18KW 30KVA / 27KW
PHASE3 Phase with Neutral
INPUT
Voltage RangeLow Line Loss110 VAC(Ph-N) ± 3 % at 50% Load ; 176 VAC(Ph-N) ± 3 % at 100% Load
Low Line    ComebackLow Line Loss Voltage + 10V
High Line    Loss300 VAC(Ph-N) ± 3 %
High Line ComebackHigh Line Loss Voltage – 10V
PhaseThree phase with ground
Power Factor≥ 0.99 at 100% Load
OUTPUT
Output voltage208/220/230/240VAC(Ph-N)
AC Voltage    Regulation± 1%
Frequency Range    (Synchronized Range)46Hz ~ 54 Hz @ 50Hz system ; 56Hz ~ 64 Hz @ 60Hz system
Frequency Range (Batt. Mode)50 Hz ± 0.1 Hz or 60Hz ± 0.1 Hz
OverloadAC mode100%~110%: 10min ; 110%~130%: 1min ; >130% : 1sec
Battery mode100%~110%: 30sec ; 110%~130%: 10sec ; >130%    : 1sec
Current Crest Ratio3:1 max
Harmonic Distortion≦ 2 % @ 100% Linear    Load; ≦ 5 % @ 100%    Non-linear Load
Transfer TimeLine←→Battery0 ms
Inverte←→Bypass0 ms (When phase lock fails, <4ms    interruption occurs from inverter to bypass)
Line←→ECO<10 ms
EFFICIENCY
AC mode> 89%> 89%> 89%> 90%
Battery Mode> 86%> 88%> 87%> 89%
BATTERY
Standard ModelType12 V / 9 Ah  12 V / 9 Ah 12 V / 9 Ah12 V / 9 Ah
Numbers20(18-20 adjustable)2 x 20(18-20 adjustable)2 x 20(18-20    adjustable)3 x 20(18-20 adjustable)
Recharge Time9 hours recover to 90% capacity
Charging    Current1.0 A ± 10% (max.)2.0 A ± 10%    (max.)2.0 A ± 10% (max.)4.0 A ± 10% (max.)
Charging Voltage273 VDC ± 1%
Long-run ModelTypeDepending on applications
Numbers18-20          
Charging Current4.0 A ± 10% (max.)4.0 A ± 10%    (max.)4.0 A ± 10% (max.)12.0 A ± 10% (max.)
Charging Voltage273 VDC ± 1%
PHYSICAL
Standard Model Dimension,DxWxH(mm)832 X250X894832 X250X1275
Long-run    ModelDimension,DxWxH(mm)609 X250X768832 X250X828
ENVIRONMENT
Operation Temperature0 ~ 40°C (the battery life will down when > 25°C)
Operation Humidity<95 % and non-condensing
Operation Altitude<1000m
Acoustic Noise LevelLess than 58dB @ 1 MeterLess than 60dB    @ 1 Meter
MANAGEMENT
Smart RS-232 / USBSupports Windows® 2000/2003/XP/Vista/2008, Windows® 7, Linux, Unix, and    MAC
USBPower management from SNMP manager and web browser